Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
PLoS One ; 19(5): e0301624, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38713678

RESUMO

Salmonella enterica serovar Typhi (S. Typhi) is the causative agent of Typhoid fever. Blood culture is the gold standard for clinical diagnosis, but this is often difficult to employ in resource limited settings. Environmental surveillance of waste-impacted waters is a promising supplement to clinical surveillance, however validating methods is challenging in regions where S. Typhi concentrations are low. To evaluate existing S. Typhi environmental surveillance methods, a novel process control organism (PCO) was created as a biosafe surrogate. Using a previous described qPCR assay, a modified PCR amplicon for the staG gene was cloned into E. coli. We developed a target region that was recognized by the Typhoid primers in addition to a non-coding internal probe sequence. A multiplex qPCR reaction was developed that differentiates between the typhoid and control targets, with no cross-reactivity or inhibition of the two probes. The PCO was shown to mimic S. Typhi in lab-based experiments with concentration methods using primary wastewater: filter cartridge, recirculating Moore swabs, membrane filtration, and differential centrifugation. Across all methods, the PCO seeded at 10 CFU/mL and 100 CFU/mL was detected in 100% of replicates. The PCO is detected at similar quantification cycle (Cq) values across all methods at 10 CFU/mL (Average = 32.4, STDEV = 1.62). The PCO was also seeded into wastewater at collection sites in Vellore (India) and Blantyre (Malawi) where S. Typhi is endemic. All methods tested in both countries were positive for the seeded PCO. The PCO is an effective way to validate performance of environmental surveillance methods targeting S. Typhi in surface water.


Assuntos
Monitoramento Ambiental , Escherichia coli , Salmonella typhi , Salmonella typhi/genética , Salmonella typhi/isolamento & purificação , Escherichia coli/genética , Escherichia coli/isolamento & purificação , Monitoramento Ambiental/métodos , Águas Residuárias/microbiologia , Febre Tifoide/microbiologia , Febre Tifoide/epidemiologia , Febre Tifoide/diagnóstico , Febre Tifoide/prevenção & controle , Humanos , Microbiologia da Água
2.
Sens Diagn ; 3(3): 421-430, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38495597

RESUMO

Nucleic acid amplification tests for the detection of SARS-CoV-2 have been an important testing mechanism for the COVID-19 pandemic. While these traditional nucleic acid diagnostic methods are highly sensitive and selective, they are not suited to home or clinic-based uses. Comparatively, rapid antigen tests are cost-effective and user friendly but lack in sensitivity and specificity. Here we report on the development of a one-pot, duplexed reverse transcriptase recombinase polymerase amplification SARS-CoV-2 assay with MS2 bacteriophage as a full process control. Detection is carried out with either real-time fluorescence or lateral flow readout with an analytical sensitivity of 50 copies per reaction. Unlike previously published assays, the RNA-based MS2 bacteriophage control reports on successful operation of lysis, reverse transcription, and amplification. This SARS-CoV-2 assay features highly sensitive detection, visual readout through an LFA strip, results in less than 25 minutes, minimal instrumentation, and a useful process internal control to rule out false negative test results.

4.
PLOS Glob Public Health ; 3(8): e0002044, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37582061

RESUMO

Diagnostics are critical tools that guide clinical decision-making for patient care and support disease surveillance. Despite its importance, developers and manufacturers often note that access to specimen panels and essential reagents is one of the key challenges in developing quality diagnostics, particularly in low-resource settings. A recent example, as the COVID-19 pandemic unfolded there was a need for clinical samples across the globe to support the rapid development of diagnostics. To address these challenges and gaps, PATH, a global nonprofit, along with its partners collaborated to create a COVID-19 biorepository to improve access to biological samples. Since then, the need for data resources to advance universal rapid diagnostic test (RDT) readers and noninvasive clinical measurement tools for screening children have also been identified and initiated. From biospecimens to data files, there are more similarities than differences in creating open-access repositories. And to ensure equitable technologies are developed, diverse sample panels and datasets are critical in the development process. Here we share one experience in creating open-access repositories as a case study to describe the steps taken, the key factors required to establish a biorepository, the ethical and legal frameworks that guided the initiative and the lessons learned. As diagnostic tools are evolving, more forms of data are critical to de-risk and accelerate early research and development (R&D) for products serving low resource settings. Creating physical and virtual repositories of freely available, well characterized, and high quality clinical and electronic data resources defray development costs to improve equitable access and test affordability.

5.
PLoS One ; 18(7): e0287814, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37467188

RESUMO

The relationship between N-antigen concentration and viral load within and across different specimens guides the clinical performance of rapid diagnostic tests (RDT) in different uses. A prospective study was conducted in Porto Velho, Brazil, to investigate RDT performance in different specimen types as a function of the correlation between antigen concentration and viral load. The study included 214 close contacts with recent exposures to confirmed cases, aged 12 years and older and with various levels of vaccination. Antigen concentration was measured in nasopharyngeal swab (NPS), anterior nares swab (ANS), and saliva specimens. Reverse transcriptase (RT)-PCR was conducted on the NPS and saliva specimens, and two RDTs were conducted on ANS and one RDT on saliva. Antigen concentration correlated well with viral load when measured in the same specimen type but not across specimen types. Antigen levels were higher in symptomatic cases compared to asymptomatic/oligosymptomatic cases and lower in saliva compared to NPS and ANS samples. Discordant results between the RDTs conducted on ANS and the RT-PCR on NPS were resolved by antigen concentration values. The analytical limit-of-detection of RDTs can be used to predict the performance of the tests in populations for which the antigen concentration is known. The antigen dynamics across different sample types observed in SARS-CoV-2 disease progression support use of RDTs with nasal samples. Given lower antigen concentrations in saliva, rapid testing using saliva is expected to require improved RDT analytical sensitivity to achieve clinical sensitivity similar to rapid testing of nasal samples.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Carga Viral , Estudos Prospectivos , COVID-19/diagnóstico , Testes Sorológicos , Saliva , Manejo de Espécimes , Sensibilidade e Especificidade , Nasofaringe
6.
Microbiol Spectr ; 11(3): e0373122, 2023 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-37166329

RESUMO

Rapid diagnostic tests (RDTs) that detect antigen indicative of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection can help in making quick health care decisions and regularly monitoring groups at risk of infection. With many RDT products entering the market, it is important to rapidly evaluate their relative performance. Comparison of clinical evaluation study results is challenged by protocol design variations and study populations. Laboratory assays were developed to quantify nucleocapsid (N) and spike (S) SARS-CoV-2 antigens. Quantification of the two antigens in nasal eluates confirmed higher abundance of N than S antigen. The median concentration of N antigen was 10 times greater than S per genome equivalent. The N antigen assay was used in combination with quantitative reverse transcription (RT)-PCR to qualify a panel composed of recombinant antigens, inactivated virus, and clinical specimen pools. This benchmarking panel was applied to evaluate the analytical performance of the SD Biosensor Standard Q COVID-19 antigen (Ag) test, Abbott Panbio COVID-19 Ag rapid test, Abbott BinaxNOW COVID-19 Ag test, and the LumiraDx SARS-CoV-2 Ag test. The four tests displayed different sensitivities toward the different panel members, but all performed best with the clinical specimen pool. The concentration for a 90% probability of detection across the four tests ranged from 21 to 102 pg/mL of N antigen in the extracted sample. Benchmarking panels provide a quick way to verify the baseline performance of a diagnostic and enable direct comparisons between diagnostic tests. IMPORTANCE This study reports the results for severe acute respiratory syndrome coronavirus-2 (SARS-COV-2) nucleocapsid (N) and spike (S) antigen quantification assays and their performance against clinical reverse transcription (RT)-PCR results, thus describing an open-access quantification method for two important SARS-CoV-2 protein analytes. Characterized N antigen panels were used to evaluate the limits of detection of four different rapid tests for SARS-CoV-2 against multiple sources of nucleocapsid antigen, demonstrating proof-of-concept materials and methodology to evaluate SARS-CoV-2 rapid antigen detection tests. Quantification of N antigen was used to characterize the relationship between viral count and antigen concentration among clinical samples and panel members of both clinical sample and viral culture origin. This contributes to a deeper understanding of protein antigen and molecular analytes and presents analytical methods complementary to clinical evaluation for characterizing the performance of both laboratory-based and point-of-care rapid diagnostics for SARS-CoV-2.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Indicadores e Reagentes , Benchmarking , Testes Diagnósticos de Rotina , Teste para COVID-19
7.
PLOS Glob Public Health ; 3(1): e0001074, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36962955

RESUMO

The typhoid conjugate vaccine is a safe and effective method for preventing Salmonella enterica serovar Typhi (typhoid) and the WHO's guidance supports its use in locations with ongoing transmission. However, many countries lack a robust clinical surveillance system, making it challenging to determine where to use the vaccine. Environmental surveillance is one alternative approach to identify ongoing transmission, but the cost to implement such a strategy is previously unknown. This paper estimated the cost of setting up and operating an environmental surveillance program for thirteen protocols that are in development, including thirteen cost components and twenty-seven pieces of equipment. Unit costs were obtained from research labs involved in protocol development and equipment information was obtained from manufacturers and the expert opinion of individuals in participating labs. We used Monte Carlo simulations to estimate the costs and the input parameters were modeled as distributions to incorporate the uncertainty. Total costs per sample including setup, overhead, and operational costs, range from $357-794 at a scale of 25 sites to $116-532 at 125 sites. Operational costs (ongoing expenditures) range from $218-584 per sample at a scale of 25 sites to $74-421 at 125 sites. Eleven of the thirteen protocols have operational costs below $200, at this higher scale. Protocols with higher up-front equipment costs benefit more from scale efficiencies and sensitivity analyses show that laboratory labor, processes, and consumables are the primary drivers of uncertainty. At scale, environmental surveillance for typhoid may be affordable (depending on the protocol, scale, and geographic context), though cost will need to be considered alongside future evaluations of test sensitivity. Opportunities to leverage existing infrastructure and multi-disease platforms may be necessary to further reduce costs.

8.
PLoS One ; 17(11): e0277835, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36409692

RESUMO

Processing and storing blood samples for future analysis of biomarkers can be challenging in resource limited environments. The preparation of dried blood spots (DBS) from finger-stick collection of whole blood is a widely used and established method as DBS are biosafe, and allow simpler field processing, storage, and transport protocols than serum or plasma. Therefore, DBS are commonly used in population surveys to assess infectious disease and/or micronutrient status. Recently, we reported that DBS can be used with the Q-plex™ Human Micronutrient 7-plex Array (MN 7-plex), a multiplexed immunoassay. This tool can simultaneously quantify seven protein biomarkers related to micronutrient deficiencies (iodine, iron and vitamin A), inflammation, and malarial antigenemia using plasma or serum. Serum ferritin, an iron biomarker, cannot be measured from DBS due to red blood cell (RBC) ferritin content confounding the results. In this study, we assess a simple blood fractionation tool that passively separates plasma from other blood components via diffusion through a membrane into a plasma collection disc (PCD). We evaluated the concordance of MN 7-plex analyte concentrations from matched panels of eighty-eight samples of PCD, DBS, and wet plasma prepared from anticoagulated venous whole blood. The results showed good correlations of >0.93 between the eluates from PCD and DBS for each analyte except ferritin; while correlations seen for plasma/PCD were weaker. However, the recovery rate of the analytes from the PCD were better than those from DBS. The serum ferritin measures from the PCD were highly correlated to wet plasma samples (0.85). This suggests that surveillance for iron status in low resource settings can be improved over the current methods restricted to only measuring sTfR in DBS. When used in combination with the MN 7-plex, all seven biomarkers can be simultaneously measured using eluates from the PCDs.


Assuntos
Micronutrientes , Oligoelementos , Humanos , Biomarcadores , Ferritinas , Ferro , Inflamação
9.
PLoS One ; 17(10): e0276582, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36282844

RESUMO

Over 71 million people are infected with hepatitis C virus (HCV) worldwide, and approximately 400,000 global deaths result from complications of untreated chronic HCV. Pan-genomic direct-acting antivirals (DAAs) have recently become widely available and feature high cure rates in less than 12 weeks of treatment. The rollout of DAAs is reliant on diagnostic tests for HCV RNA to identify eligible patients with viremic HCV infections. Current PCR-based HCV RNA assays are restricted to well-resourced central laboratories, and there remains a prevailing clinical need for expanded access to decentralized HCV RNA testing to provide rapid chronic HCV diagnosis and linkage to DAAs in outpatient clinics. This paper reports a rapid, highly accurate, and minimally instrumented assay for HCV RNA detection using reverse transcription recombinase polymerase amplification (RT-RPA). The assay detects all HCV genotypes with a limit of detection of 25 copies per reaction for genotype 1, the most prevalent in the United States and worldwide. The clinical sensitivity and specificity of the RT-RPA assay were both 100% when evaluated using 78 diverse clinical serum specimens. The accuracy, short runtime, and low heating demands of RT-RPA may enable implementation in a point-of-care HCV test to expand global access to effective treatment via rapid chronic HCV diagnosis.


Assuntos
Hepatite C Crônica , Hepatite C , Humanos , Recombinases/genética , Hepacivirus/genética , Antivirais , Hepatite C Crônica/diagnóstico , Hepatite C/diagnóstico , Técnicas de Amplificação de Ácido Nucleico , Sensibilidade e Especificidade , RNA , RNA Viral/genética
10.
PLoS One ; 17(9): e0274415, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36178936

RESUMO

Lipoarabinomannan (LAM), a component of the Mycobacterium tuberculosis (MTB) cell wall, is detectable in the urine of MTB infected patients with active tuberculosis (TB). LAM-specific antibodies (Igs) have been developed by a variety of traditional and recombinant methods for potential use in a rapid diagnostic test (RDT). We evaluated the analytical performance of the TB LAM Igs to identify pairs that offer superior performance over existing urine LAM tests. We assessed 25 new and 4 existing Igs in a matrixed format using a multiplex electrochemiluminescence-based liquid immunoassay. A total of 841 paired Ig combinations were challenged with in vitro cultured LAM (cLAM) derived from MTB strains representing diverse phylogenetic lineages, alongside urinary LAM (uLAM) from the urine of adults with active pulmonary TB. Analytical sensitivity of down-selected Ig pairs was determined using MTB Aoyama-B cLAM, while diagnostic accuracy was determined using clinical samples. When testing cLAM, the reactivity of Ig pairs was similar across MTB lineages 1-4 but lineage 5:6 had significantly more reactivity among Ig pairs. Overall, 41 Ig pairs had a strong binding affinity to cLAM, as compared to the reference pair of S4-20/A194-01, and 28 Ig pairs therein exhibited a strong affinity for both cLAM and uLAM. Retrospective testing on clinical urine specimens demonstrated varying sensitivities (12-80%) and specificities (14-100%). The five top pairs had a similar analytical limit of detection to the reference pair but in four instances, the sensitivity and specificity with clinical uLAM samples was poor. Overall, epitopes presented by uLAM are different from cLAM, which may affect antibody performance when testing uLAM in patient samples. Several new Ig pairs had similar ranges of high sensitivity to cLAM but overall, there were no new candidate Ig pairs identified in this round of screening with increased performance with uLAM as compared to an existing optimal pair.


Assuntos
Infecções por HIV , Mycobacterium tuberculosis , Tuberculose dos Linfonodos , Adulto , Testes Diagnósticos de Rotina/métodos , Epitopos , Infecções por HIV/diagnóstico , Humanos , Lipopolissacarídeos , Filogenia , Estudos Retrospectivos , Sensibilidade e Especificidade
11.
Int J Infect Dis ; 117: 287-294, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35149246

RESUMO

OBJECTIVES: This study assesses and compares the performance of different swab types and specimen collection sites for SARS-CoV-2 testing, to reference standard real-time reverse transcriptase-polymerase chain reaction (RT-PCR) and viral culture. METHODS: Symptomatic adults with COVID-19 who visited routine COVID-19 testing sites used spun polyester and FLOQSwabs to self-collect specimens from the anterior nares and tongue. We evaluated the self-collected specimen from anterior nares and tongue swabs for the nucleocapsid (N) or spike (S) antigen of SARS-CoV-2 by RT-PCR and then compared these results with results from RT-PCR and viral cultures from nurse-collected nasopharyngeal swabs. RESULTS: Diagnostic sensitivity was highest for RT-PCR testing conducted using specimens from the anterior nares collected on FLOQSwabs (84%; 95% CI 68-94%) and spun polyester swabs (82%; 95% CI 66-92%), compared to RT-PCR tests conducted using specimens from nasopharyngeal swabs. Relative to viral culture from nasopharyngeal swabs, diagnostic sensitivities were higher for RT-PCR and antigen testing of anterior nares swabs (91-100%) than that of tongue swabs (18-81%). Antigen testing of anterior nares swabs had higher sensitivities against viral culture (91%) than against nasopharyngeal RT-PCR (38-70%). All investigational tests had high specificity compared with nasopharyngeal RT-PCR. Spun polyester swabs are equally effective as FLOQSwabs for anterior nasal RT-PCR testing. CONCLUSIONS: We found that anterior nares specimens were more sensitive than tongue swab specimens or antigen testing for detecting SARS-CoV-2 by RT-PCR. Thus, self-collected anterior nares specimens may represent an alternative method for diagnostic SARS-CoV-2 testing in some settings.


Assuntos
COVID-19 , Ácidos Nucleicos , Adulto , COVID-19/diagnóstico , Teste para COVID-19 , Humanos , Nasofaringe , Nucleocapsídeo/genética , Reação em Cadeia da Polimerase , SARS-CoV-2/genética , Sensibilidade e Especificidade , Manejo de Espécimes/métodos , Língua
12.
PLoS One ; 17(1): e0262761, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35081146

RESUMO

Eradication of poliovirus (PV) is a global public health priority, and as clinical cases decrease, the role of environmental surveillance becomes more important. Persistence of PV and the environmental factors that influence it (such as temperature and sample type) are an important part of understanding and interpreting positive environmental surveillance samples. The objective of this study was to evaluate the persistence of poliovirus type 2 (PV2) and type 3 (PV3) in wastewater and sediment. Microcosms containing either 1) influent wastewater or 2) influent wastewater with a sediment matrix were seeded with either PV2 or PV3, and stored for up to 126 days at three temperatures (4°C, room temperature [RT], and 30°C). Active PV in the liquid of (1), and the sediment and liquid portions of (2) were sampled and quantified at up to 10 time points via plaque assay and RT-qPCR. A suite of 17 models were tested for best fit to characterize decay of PV2 and PV3 over time and determine the time points at which >90% (T90) and >99% (T99) reduction was reached. Linear models assessed the influence of experimental factors (matrix, temperature, virus type and method of detection) on the predicted T90 and T99 values. Results showed that when T90 was the dependent variable, virus type, matrix, and temperature significantly affected decay, and there was a clear interaction between the sediment matrix and temperature. When T99 was the dependent variable, only temperature and matrix type significantly influenced the decay metric. This study characterizes the persistence of both active and molecular PV2 and PV3 in relevant environmental conditions, and demonstrates that temperature and sediment both play important roles in PV viability. As eradication nears and clinical cases decrease, environmental surveillance and knowledge of PV persistence will play a key role in understanding the silent circulation in endemic countries.


Assuntos
Monitoramento Ambiental , Sedimentos Geológicos/virologia , Poliovirus/isolamento & purificação , Águas Residuárias/virologia
13.
PLoS One ; 16(11): e0259509, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34735520

RESUMO

A lack of comparative data across laboratories is often a barrier to the uptake and adoption of new technologies. Furthermore, data generated by different immunoassay methods may be incomparable due to a lack of harmonization. In this multicenter study, we describe validation experiments conducted in a single lab and cross-lab comparisons of assay results to assess the performance characteristics of the Q-plex™ 7-plex Human Micronutrient Array (7-plex), an immunoassay that simultaneously quantifies seven biomarkers associated with micronutrient (MN) deficiencies, inflammation and malarial antigenemia using plasma or serum; alpha-1-acid glycoprotein, C-reactive protein, ferritin, histidine-rich protein 2, retinol binding protein 4, soluble transferrin receptor, and thyroglobulin. Validations included repeated testing (n = 20 separately prepared experiments on 10 assay plates) in a single lab to assess precision and linearity. Seven independent laboratories tested 76 identical heparin plasma samples collected from a cohort of pregnant women in Niger using the same 7-plex assay to assess differences in results across laboratories. In the analytical validation experiments, intra- and inter-assay coefficients of variation were acceptable at <6% and <15% respectively and assay linearity was 96% to 99% with the exception of ferritin, which had marginal performance in some tests. Cross-laboratory comparisons showed generally good agreement between laboratories in all analyte results for the panel of 76 plasma specimens, with Lin's concordance correlation coefficient values averaging ≥0.8 for all analytes. Excluding plates that would fail routine quality control (QC) standards, the inter-assay variation was acceptable for all analytes except sTfR, which had an average inter-assay coefficient of variation of ≥20%. This initial cross-laboratory study demonstrates that the 7-plex test protocol can be implemented by users with some experience in immunoassay methods, but familiarity with the multiplexed protocol was not essential.


Assuntos
Ferritinas/metabolismo , Inflamação/metabolismo , Proteína C-Reativa/metabolismo , Imunoensaio , Estudos Multicêntricos como Assunto , Proteínas/metabolismo , Software
14.
PLoS One ; 16(11): e0258819, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34758052

RESUMO

Inexpensive, simple, rapid diagnostics are necessary for efficient detection, treatment, and mitigation of COVID-19. Assays for SARS-CoV2 using reverse transcription polymerase chain reaction (RT-PCR) offer good sensitivity and excellent specificity, but are expensive, slowed by transport to centralized testing laboratories, and often unavailable. Antigen-based assays are inexpensive and can be rapidly mass-produced and deployed at point-of-care, with lateral flow assays (LFAs) being the most common format. While various manufacturers have produced commercially available SARS-Cov2 antigen LFAs, access to validated tests remains difficult or cost prohibitive in low-and middle-income countries. Herein, we present a visually read open-access LFA (OA-LFA) using commercially-available antibodies and materials for the detection of SARS-CoV-2. The LFA yielded a Limit of Detection (LOD) of 4 TCID50/swab of gamma irradiated SARS-CoV-2 virus, meeting the acceptable analytical sensitivity outlined by in World Health Organization target product profile. The open-source architecture presented in this manuscript provides a template for manufacturers around the globe to rapidly design a SARS-CoV2 antigen test.


Assuntos
Antígenos Virais/imunologia , Teste para COVID-19/métodos , COVID-19/diagnóstico , COVID-19/imunologia , Proteínas do Nucleocapsídeo de Coronavírus/imunologia , SARS-CoV-2/imunologia , COVID-19/virologia , Humanos , Limite de Detecção , Sistemas Automatizados de Assistência Junto ao Leito , RNA Viral/imunologia , Sensibilidade e Especificidade
15.
ACS Omega ; 6(39): 25116-25123, 2021 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-34608447

RESUMO

The global COVID-19 pandemic has created an urgent demand for large numbers of inexpensive, accurate, rapid, point-of-care diagnostic tests. Analyte-based assays are suitably rapid and inexpensive and can be rapidly mass-produced, but for sufficiently accurate performance, they require highly optimized antibodies and assay conditions. We used an automated liquid handling system, customized to handle arrays of lateral flow (immuno)assays (LFAs) in a high-throughput screen, to identify anti-nucleocapsid antibodies that will perform optimally in an LFA. We tested 1021 anti-nucleocapsid antibody pairs as LFA capture and detection reagents with the goal of highlighting pairs that have the greatest affinity for the nucleocapsid protein of SARS-CoV-2 within the LFA format. In contrast to traditional antibody screening methods (e.g., ELISA, bio-layer interferometry), the method described here integrates real-time reaction kinetics with transport in, and immobilization directly onto, nitrocellulose. We have identified several candidate antibody pairs that are suitable for further development of an LFA for SARS-CoV-2.

16.
ACS Omega ; 6(31): 20139-20148, 2021 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-34373846

RESUMO

Severe acute respiratory coronavirus-2 (SARS-CoV-2) is a novel viral pathogen and therefore a challenge to accurately diagnose infection. Asymptomatic cases are common and so it is difficult to accurately identify infected cases to support surveillance and case detection. Diagnostic test developers are working to meet the global demand for accurate and rapid diagnostic tests to support disease management. However, the focus of many of these has been on molecular diagnostic tests, and more recently serologic tests, for use in primarily high-income countries. Low- and middle-income countries typically have very limited access to molecular diagnostic testing due to fewer resources. Serologic testing is an inappropriate surrogate as the early stages of infection are not detected and misdiagnosis will promote continued transmission. Detection of infection via direct antigen testing may allow for earlier diagnosis provided such a method is sensitive. Leading SARS-CoV-2 biomarkers include spike protein, nucleocapsid protein, envelope protein, and membrane protein. This research focuses on antibodies to SARS-CoV-2 spike protein due to the number of monoclonal antibodies that have been developed for therapeutic research but also have potential diagnostic value. In this study, we assessed the performance of antibodies to the spike glycoprotein, acquired from both commercial and private groups in multiplexed liquid immunoassays, with concurrent testing via a half-strip lateral flow assays (LFA) to indicate antibodies with potential in LFA development. These processes allow for the selection of pairs of high-affinity antispike antibodies that are suitable for liquid immunoassays and LFA, some of which with sensitivity into the low picogram range with the liquid immunoassay formats with no cross-reactivity to other coronavirus S antigens. Discrepancies in optimal ranking were observed with the top pairs used in the liquid and LFA formats. These findings can support the development of SARS-CoV-2 LFAs and diagnostic tools.

17.
Analyst ; 146(9): 2851-2861, 2021 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-33949378

RESUMO

The number of people living with HIV continues to increase with the current total near 38 million, of which about 26 million are receiving antiretroviral therapy (ART). These treatment regimens are highly effective when properly managed, requiring routine viral load monitoring to assess successful viral suppression. Efforts to expand access by decentralizing HIV nucleic acid testing in low- and middle-income countries (LMICs) has been hampered by the cost and complexity of current tests. Sample preparation of blood samples has traditionally relied on cumbersome RNA extraction methods, and it continues to be a key bottleneck for developing low-cost POC nucleic acid tests. We present a microfluidic paper-based analytical device (µPAD) for extracting RNA and detecting HIV in serum, leveraging low-cost materials, simple buffers, and an electric field. We detect HIV virions and MS2 bacteriophage internal control in human serum using a novel lysis and RNase inactivation method, paper-based isotachophoresis (ITP) for RNA extraction, and duplexed reverse transcription recombinase polymerase amplification (RT-RPA) for nucleic acid amplification. We design a specialized ITP system to extract and concentrate RNA, while excluding harsh reagents used for lysis and RNase inactivation. We found the ITP µPAD can extract and purify 5000 HIV RNA copies per mL of serum. We then demonstrate detection of HIV virions and MS2 bacteriophage in human serum within 45-minutes.


Assuntos
Infecções por HIV , Isotacoforese , Infecções por HIV/diagnóstico , Humanos , Técnicas de Amplificação de Ácido Nucleico , RNA/genética , RNA Viral/genética , Recombinases/genética , Recombinases/metabolismo , Transcrição Reversa , Sensibilidade e Especificidade
18.
Analyst ; 146(8): 2449-2462, 2021 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-33899053

RESUMO

The COVID-19 pandemic has put the spotlight on the urgent need for integrated nucleic acid tests (NATs) for infectious diseases, especially those that can be used near patient ("point-of-care", POC), with rapid results and low cost, but without sacrificing sensitivity or specificity of gold standard PCR tests. In the US, the Clinical Laboratory Improvement Amendments Certificate of Waiver (CLIA-waiver) is mandated by the Food and Drug Administration (FDA) and designated to any laboratory testing with high simplicity and low risk for error, suitable for application in the POC. Since the first issuance of CLIA-waiver to Abbot's ID NOW Influenza A&B in 2015, many more NAT systems have been developed, received the CLIA-waiver in the US or World Health Organization (WHO)'s pre-qualification, and deployed to the front line of infectious disease detection. This review highlights the regulatory process for FDA and WHO in evaluating these NATs and the technology innovation of existing CLIA-waived systems. Understanding the technical advancement and challenges, unmet needs, and the trends of commercialization facilitated through the regulatory processes will help pave the foundation for future development and technology transfer from research to the market place.


Assuntos
COVID-19 , Doenças Transmissíveis , Ácidos Nucleicos , Doenças Transmissíveis/diagnóstico , Humanos , Ácidos Nucleicos/genética , Pandemias , Sistemas Automatizados de Assistência Junto ao Leito , Testes Imediatos , SARS-CoV-2
19.
Viruses ; 13(3)2021 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-33803454

RESUMO

Enteric viruses, such as poliovirus, are a leading cause of gastroenteritis, which causes 2-3 million deaths annually. Environmental surveillance of wastewater supplements clinical surveillance for monitoring enteric virus circulation. However, while many environmental surveillance methods require liquid samples, some at-risk locations utilize pit latrines with waste characterized by high solids content. This study's objective was to develop and evaluate enteric virus concentration protocols for high solids content samples. Two existing protocols were modified and tested using poliovirus type 1 (PV1) seeded into primary sludge. Method 1 (M1) utilized acid adsorption, followed by 2 or 3 elutions (glycine/sodium chloride and/or threonine/sodium chloride), and skimmed milk flocculation. Method 2 (M2) began with centrifugation. The liquid fraction was filtered through a ViroCap filter and eluted (beef extract/glycine). The solid fraction was eluted (beef extract/disodium hydrogen phosphate/citric acid) and concentrated by skimmed milk flocculation. Recovery was enumerated by plaque assay. M1 yielded higher PV1 recovery than M2, though this result was not statistically significant (26.1% and 15.9%, respectively). M1 was further optimized, resulting in significantly greater PV1 recovery when compared to the original protocol (p < 0.05). This method can be used to improve understanding of enteric virus presence in communities without liquid waste streams.


Assuntos
Monitoramento Ambiental/métodos , Poliovirus/isolamento & purificação , Esgotos/virologia , Resíduos Sólidos/análise , Carga Viral/métodos , Infecções por Enterovirus/prevenção & controle , Floculação , Gastroenterite/prevenção & controle , Gastroenterite/virologia , Humanos , Poliomielite/prevenção & controle , Ensaio de Placa Viral/métodos , Microbiologia da Água
20.
BMC Microbiol ; 21(1): 29, 2021 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-33468047

RESUMO

BACKGROUND: Salmonella enterica remains a leading cause of food-borne diseases worldwide. Serotype information is important in food safety and public health activities to reduce the burden of salmonellosis. In the current study, two methods were used to determine serotypes of 111 strains of Salmonella isolated from poultry feces in Burkina Faso. First, Salmonella Multiplex Assay for Rapid Typing (SMART) Polymerase Chain Reaction (PCR) was used to determine the serovars of the S. enterica isolates. Second, serovar prediction based on whole genome sequencing (WGS) data was performed using SeqSero 2.0. RESULTS: Among the 111 Salmonella isolates, serotypes for 17 (15.31%) isolates were identified based on comparison to a panel of representative SMART codes previously determined for the 50 most common serovars in the United States. Forty-four (44) new SMART codes were developed for common and uncommon serotypes. A total of 105 (94.59%) isolates were serotyped using SeqSero 2.0 for serovar prediction based on WGS data. CONCLUSION: We determined that SeqSero 2.0 was more comprehensive for identifying Salmonella serotypes from Burkina Faso than SMART PCR.


Assuntos
Aves Domésticas/microbiologia , Salmonella/classificação , Salmonella/genética , Sorotipagem/métodos , Animais , Burkina Faso , Eletroforese Capilar , Fezes/microbiologia , Microbiologia de Alimentos , Reação em Cadeia da Polimerase Multiplex , Filogenia , Salmonella/isolamento & purificação , Sequenciamento Completo do Genoma
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA